Lang
  • en
  • se
  • dk
  • NO
  • Kontakta oss
  • Nedladdningar
  • Shopping Cart Shopping Cart
    0Shopping Cart
  • Tillbaka
  • Produkter
    • Alla produkter
    • Ljudmätare
    • Ljudkällor
    • Övervakning av utomhusbuller
    • Akustisk kamera
    • Testsystem
    • Kalibratorer
    • Utomhusmikrofoner
    • Vibrationer
    • Programvaror
  • Användningsområden
  • Uthyrning
  • Kalibrering – SE
  • Support
  • Utställningar
  • Nedladdningar
  • Om Norsonic
  • Kontakta oss
  • Upphämtning vid service
  • cart-icon
  • Menu Menu
Hem / Produkter / Nor850 Reporting Software
Nor850-software
Nor850-software
Category: Programvaror

Nor850 Reporting Software

Be om info/pris

Programvara med moduler för mätning och beräkning av byggakustik, ljudeffekt, ”appliance noise”  ljudintensitet (endast beräkning) och generell ljudmätning. Även med softwaremodul för kontroll av Nor850 frontend alternativt en eller flera Nor140/Nor145/Nor150 ljudnivåmätare.

Related products

  • NorVirtual-PC

    Programvaror

    NorVirtual

    Add to cart Add to cart Read more Detaljinfo Detaljinfo Detaljinfo
  • Programvaror

    Nor850 programvara (850/BA2): Byggakustik ISO 10140

    Add to cart Add to cart Read more Detaljinfo Detaljinfo Detaljinfo
  • Nor1038-NorVibraTest

    Programvaror

    Nor1038 NorVibraTest

    Add to cart Add to cart Read more Detaljinfo Detaljinfo Detaljinfo
  • Programvaror

    Sound of Numbers

    Add to cart Add to cart Read more Detaljinfo Detaljinfo Detaljinfo

Användningsområden

  • Rapportering av byggnadsakustik
  • Rapportering av ljudintensitet
  • Rapportering av ljudeffekt

Nor850 Reporting Software

text

The full range of Standards for building acoustics such as the in-situ ISO 16283, laboratory ISO 10140 and the national versions such as American ASTM Standards, are selectable. Calculation properties as well as informative text for the excel reports are inserted and edited for the final calculation of the sound insulation indices or sound power value.

With the latest upgrade to version 3, the Nor850 allow pre-defined collections of multiple measurement tasks to be uploaded to the instrument prior to test.

Customers may enhance their Nor850 Reporting system to a full-blooded Nor850 Multichannel system at any time.

Användningsområden

text

Building acoustics reporting

text

Measurements taken manually by use of the Norsonic sound level meters Nor140 or Nor150 and stored in the PC, are imported easily into the reporting modules. Level, reverberation or background measurement files are included into the respective table folders by simple drag&drop technique. Even complete building acoustics files containing all data in one file may be imported.

The full range of Standards for building acoustics such as the in-situ ISO 16283, laboratory ISO 10140 and the national versions such as American ASTM Standards, are selectable. Calculation properties as well as informative text for the excel reports are inserted and edited for the final calculation of the sound insulation indices or sound power value.

Sound power reporting

text

As described in the Building Acoustic mode, existing measurement files in a PC may be imported into the Nor850 for calculation of the final Sound Power results. The Sound Power calculations is done using the range of pre-defined Standards in the ISO 3740 series.

Sound intensity reporting

text

In the Nor850 software you can change all settings the same way as in the Nor150. However, copying and analysing the measurements is easier on a larger screen. The Nor850 software provides intuitive visual tools for editing.

Copy segments or surfaces, view intermediate results of a subset of segments, exclude segments, surfaces or bands. If desired, the measurement may be up/downgraded between Survey/Engineering, and the weighted frequency range may be changed.

Nor850 displays all the information as the Nor150, including the Scope Selector and all functions. In addition, the results are mapped onto a 2D/3D surface for noise mapping.

A typical application may be the case where limited time did not allow for a full definition of segments before measurement. All measurements can be made on a single surface where the areas are not defined. By opening up two measurement projects in Nor850, you define a new total measurement surface and copy/paste each measured segment into correct locations in the new project.

Measured results are available in various windows containing graphs, tables, navigation pane etc.

 

Nor850 with Sound Intensity option includes report generation for the ISO 9614 part 1 and part 2 Standards. Fill in the essential information about the measurement, and generate the measurement report.

 

Measured results displayed as 2D surface and 3D surface together, along with the Scope Selector (navigator) and colour range adjustment pane.

Nedladdningar

text
Brochurer

Product range catalogue

  • Product range catalogue - English -

    Norsonic_productrange_2024-2025.pdf (0.01GB)
    Released
    Nedladdningar
  • Catálogo de productos - Español -

    Norsonic_product_catalogue_Spanish.pdf (0.01GB)
    Released
    Nedladdningar
Software

Nor850 reporting software

  • Nor850 -

    Nor850-2.2-0313-InstallationPack.zip (0.05GB)
    Released
    Nedladdningar
  • Nor850 - 2.3.190605

    Nor850-2.3.190605.zip (0.07GB)
    Released
    Nedladdningar
  • Nor850 - 3.1.221130

    Nor850-3.1.221130.exe (0.08GB)
    Released 22/12/2022
    Nedladdningar
  • Nor850 - 3.2.241008

    Nor850-3.2.241008.zip (0.09GB)
    Released 06/11/2024
    Nedladdningar
  • Nor850 - 4.1.250505

    Nor850-4.1.250505.zip (0.11GB)
    Released 22/04/2025
    Nedladdningar
  • Release note for Nor850 - version 4.1

    Release-note-Nor850-v-4.1-May-2025.pdf (145.68KB)
    Released 06/05/2025

    Release note for Nor850 version 4.1

    Nedladdningar
Product data

Nor850 software

  • Nor850 software highlights version 3 -

    Short-form-Nor850-v3-0121_web.pdf (1678.89KB)
    Released 01/01/2021
    Nedladdningar

Relaterade produkter för

Nor850 Reporting Software

Se mer
Nor145 ljudmätare
cart-icon

Ljudmätare

Nor145 Ljudmätare

Nor150
cart-icon

Ljudmätare

Nor150 2-kanals ljudmätare

Nor140
cart-icon

Ljudmätare

Nor140 Ljudmätare

Se mer

Support

Har du några frågor eller
behöver du support?


SUPPORT

Call Icon Mail Icon

Kontakta oss

Norsonic AB
Hermansrovägen 8
285 36 Markaryd

0433- 122 33
info@norsonic.se

Genvägar

Om Norsonic
Försäljningsvillkor
Miljöprofil
Sekretesspolicy NorVirtual App

Hjälp

Support
Nedladdningar

Nyhetsbrev

Anmäl dig till vårt nyhetsbrev och håll dig uppdaterad om nyheter från Norsonic.

(Obligatoriskt)
  • © 2025 Norsonic
  • Sekretesspolicy
  • Laget av NYG

Scroll to top Scroll to top Scroll to top
[product_name] lades till i kontaktformuläret

 Stäng meddelandet för att fortsätta att titta på våra produkter eller gå direkt till kontaktformuläret.

Stäng Se kontaktformulär
[product_name] lades till i kontaktformuläret

 Stäng meddelandet för att fortsätta att titta på våra produkter eller gå direkt till kontaktformuläret.

Stäng Till kontaktformulär
Förfrågan skickad!

Stäng
Din hendelse er sendt!

Vi svara inom 3 arbetsdagar. Du kommer att få en kopia via e-post.

Stäng

Din hendelse er sendt!

Vi vil svare deg i løpet av 3 virkedager. Du vil motta en kopi av din henvendelse på e-post.

Lukk